Roofs | Perforated trays 160/600 (α)
System TP160-DK60
Rw 56 | RA 50 | RA,tr 43
Avis technique RE 2020 CSTB FDES
1 2 3 4
System composition
  • 1 160/600 perforated tray
  • 2 Low-density glass wool insulation
  • 3 CTBH P5 particle board, 22 mm
  • 4 PHONOTECH DK60 acoustic panel
System Characteristics
Dimensions
Length
1200 mm
Width
600 mm
Total thickness
264 mm
Technical
Acoustic reduction
Rw (C; Ctr) = 56 (-6 ; -13) dB
Weight (kg/m²)
48,81
U (W/m².K)
0,14
Documents
Assembly instructions
Certifications
Avis technique RE 2020 CSTB FDES

To find out more about our insulation panels and made-to-measure solutions, contact us.

Contactez-nous
COPYRIGHT © 2024 ALL RIGHTS RESERVED.